Features
-
Signal management system with our own patent law which has great advantages Of online setting, real-time monitoring, self testing and flow rate control to ensure high performance and safe operation.
-
Low current system design also ensures operation safety.
-
Different temperature setting for various samples ensures complete sample digestion so as to get more accurate measuring data.
-
Adjust cooling module power according to sampling volume which improves drying performance to ensure dry gas into the detector.
-
Automatic leak check system to avoid operation mistakes and improve instrument performance, so as to ensure operation safety and instrument’s Safety.
-
Flow rate controlling system to avoid any effect caused by flow rate fluctuation which Ensure accurate data.
-
TOC detector with 24 bits data solution extends monitoring range. Controlling system With 32bin processing technology greatly improves performance.
SAMPLE MEASUREMENT PROCESSING MONITORING
Set different Name, concentration and sample volume
Real-time sample reaction
On-line AVG and RSD calculation of testing results
DISPLAY AND MONITORING OF SAMPLING
Sampling volume real-time monitoring
Automatic sample draining monitoring
Real time display and monitoring for heating, cooling
And furnace temperature
Auto Switch of Sampling and Draining
Acidification operation by peristaltic pumps
SCANNING CURVES
Samples Curves shows in the same coordinate system
For easy reading of repeatability
PARAMETER SETTING INTERFACE
Setting for heating and cooling temperature;
Acidification sampling and draining time; Basic setting
For Pump, valve and temperature control
Press “TC ˮ Clean, the system will automatically start
Drain-add Sodium per sulfate-Draining-Sampling-Draining
HALOGEN SCRUBBER DESIGN
Remove Halogen and Moisture
Avoid any effect on the results caused by impurities
FOUR IN ONE TIC REACTOR DESIGN
Helpful to remove inorganic carbon by acidification and heating digestion
Cooling function to remove moisture in carbon dioxide
Gas buffer design to avoid parts broken caused by high pressure
High moisture removal function
HIGH TEMPERATURE PYROLYSIS SYSTEM
Complete pyrolysis for samples with high temperature
Set different pyrolysis temperature for various samples
NDIR HIGH EFFICIENCY DETECTOR
Detector with special surface treatment technology to ensure ideal performance
24 bit A/D Converter to ensure stable data, low noise, and wide measurement
Range and high speed
32bin signal processing technology to ensure the instrument’s content
Temperature functions with 0.01°C temperature tolerance.