SNIR-826 is self-developed by Stalwart to replace NIR Quest aiming features high performance cost less, 900-2600nm NIR, Near Infrared spectrometer with 512 pixels, InGaAs cooled down to -20ºC, resulting in low noise, 2 times higher SNR, better reliability, measuring results do not change with ambient temperatures.

Allow for custom or preconfigured wavelength range, resolution by changing grating lines or slit size. Three common standard maximum wavelength are SNIR-817 900-1700 nm, SNIR-821 900-2100 nm , SNIR-826 900-2600 nm.

Crossed C-T optical bench design the higher sensitivity improve measure accuracy and detect tiny change spectrum, the optimized optical resolution level is superior for NIR spectrometer manufacturing.

  • SNIR-860 covers 900-2500nm NIR spectrometer developed by Stalwart for customers have less budget NIR requirements.
  • It uses cooled InGaAs detector with 512 pixels, Cooled down to -20ºC.
  • Compact size fit to a wide system integration in industrial measurement.
  • SMA905 fiber input or free-space
  • USB powered and 5V DC UART power
  • Free SDK package for OEM customers integration


Quantity :
  • Features
  • Specifications
  • Application
  • Literature

Features

  • Advanced NIR spectrometer craftsmanship
  • Widest NIR range: 900-2600 nm 
  • Extendable range from UV VIS to Mid IR: 200-5000 nm
  • Free NIR spectrometer software
  • Global leading NIR spectrometer technology from Manufacturer with 20 year
  • Custom or preconfigured wavelength range and optical resolution

Specifications

Detector

Model

Cooled Linear InGaAs CCD, Cooled down to -20ºC

Spectral Range

900-1700nm, 900-2100nm, 900-2500 nm

Effective Pixels

512 pixels

Pixels Dimension

25μm×250μm

Full Range

~17.5 Me-

Dynamic 12700

Sensitivity

160 nV/e-

Peak-value 2300nm
Dark noise 400 uV rms

Optical parameters

Wavelength Range

900-2500nm (Customized)

Resolution

5-50nm(depend on slit & spectral range)

Signal-To-Noise

>3000:1

Working Humidity

< 90%RH

Optical

Optical Design

f/4 crossed asymmetrical C-T

Confocal distance
82.3 mm for incidence / 121.5 mm for output

Incident Slit

5, 10, 25, 50, 100, or 200 μm(Customized)

Incident Interface

SMA905 connector, free space

ELECTRICAL

A/D Conversion Resolution

18 bit (output 16bit)

Integration Time

7.8ms- 256s

Data Output

USB 2.0

Supply Voltage

5V DC±5% 

Current

<3 A

Storage Temperature

-20°C to +70°C

Working Temperature -10°C to +50°C

PHYSICAL 

Dimension

215×130×53 mm^3

Weight

1.8kg

Model

SNIR-817

SNIR-821

SNIR-826

SNIR-85A

Spectral range

900-1700nm

900-2100nm

900-2600nm

1510-1590nm

Spectral resolution 25um slit

3-4nm

4-5nm

6-8nm

<0.3nm

Effective pixels

512

Pixel size

25×500μm

Detector

High performance TE-cooled InGaAs

Cooled

TE-cooled down to -20℃

SNR

10000:1

Dynamic range

13000:1

A/D resolution

18 bit 150kHz

Operating temperature

-20℃-45℃

Connector

SMA905, free space

Entrance aperture

5,15,25,50,100,200,300μm, available in custom length

PC interface

USB2.0 High speed/full speed

Integral time

1ms ~ 256s

 

Application

  • Chemical composition of Plastics, Polymers
  • Waste water detection
  • Water, Protein, Fat contents of grains
  • Carbonization characterization analysis during Paper making and pulp processing
  • Online monitoring Chinese herb production
  • Solar cell detection
  • QA/QC inspection of pharmaceutical ingredients
  • Soils component analysis
  • NIR laser characterization
  • Hydrocarbon analysis in oil and gas

Features

  • Advanced NIR spectrometer craftsmanship
  • Widest NIR range: 900-2600 nm 
  • Extendable range from UV VIS to Mid IR: 200-5000 nm
  • Free NIR spectrometer software
  • Global leading NIR spectrometer technology from Manufacturer with 20 year
  • Custom or preconfigured wavelength range and optical resolution

Specifications

Detector

Model

Cooled Linear InGaAs CCD, Cooled down to -20ºC

Spectral Range

900-1700nm, 900-2100nm, 900-2500 nm

Effective Pixels

512 pixels

Pixels Dimension

25μm×250μm

Full Range

~17.5 Me-

Dynamic 12700

Sensitivity

160 nV/e-

Peak-value 2300nm
Dark noise 400 uV rms

Optical parameters

Wavelength Range

900-2500nm (Customized)

Resolution

5-50nm(depend on slit & spectral range)

Signal-To-Noise

>3000:1

Working Humidity

< 90%RH

Optical

Optical Design

f/4 crossed asymmetrical C-T

Confocal distance
82.3 mm for incidence / 121.5 mm for output

Incident Slit

5, 10, 25, 50, 100, or 200 μm(Customized)

Incident Interface

SMA905 connector, free space

ELECTRICAL

A/D Conversion Resolution

18 bit (output 16bit)

Integration Time

7.8ms- 256s

Data Output

USB 2.0

Supply Voltage

5V DC±5% 

Current

<3 A

Storage Temperature

-20°C to +70°C

Working Temperature -10°C to +50°C

PHYSICAL 

Dimension

215×130×53 mm^3

Weight

1.8kg

Model

SNIR-817

SNIR-821

SNIR-826

SNIR-85A

Spectral range

900-1700nm

900-2100nm

900-2600nm

1510-1590nm

Spectral resolution 25um slit

3-4nm

4-5nm

6-8nm

<0.3nm

Effective pixels

512

Pixel size

25×500μm

Detector

High performance TE-cooled InGaAs

Cooled

TE-cooled down to -20℃

SNR

10000:1

Dynamic range

13000:1

A/D resolution

18 bit 150kHz

Operating temperature

-20℃-45℃

Connector

SMA905, free space

Entrance aperture

5,15,25,50,100,200,300μm, available in custom length

PC interface

USB2.0 High speed/full speed

Integral time

1ms ~ 256s

 

Application

  • Chemical composition of Plastics, Polymers
  • Waste water detection
  • Water, Protein, Fat contents of grains
  • Carbonization characterization analysis during Paper making and pulp processing
  • Online monitoring Chinese herb production
  • Solar cell detection
  • QA/QC inspection of pharmaceutical ingredients
  • Soils component analysis
  • NIR laser characterization
  • Hydrocarbon analysis in oil and gas

Related Products