SAA-Series
Atomic Absorption Spectrophotometer
Quantity :
  • Features
  • Specifications
  • Accessories
  • Literature

Features

1.Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.

2. Comprehensive and safe intelligent gas control module.

3. Excellent full band deuterium lamp background correction technology and high-performance self absorption double background correction.

4. Fully automatic instrument control, light source supports high-performance element lamp, and can be completed quickly with one key.

5. Original lamp position eight lamp holder 360 degree rotation design.

6. Novel atomizer and intelligent elevator.

7. Simple, professional, automatic and fully operated RG WIN AAS workstation software under MS window system.

Specifications

Models

SAA-782

SAA-784

SAA-788

SAA-790

Optical System

Single Beam

Double Beam

Monochromator

Czerny-Turner type, focal lengths at

Grating

Holographic diffraction with 1800 lines/mm

Wavelength Range

190-900 nm

Slits

Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm

Wavelength Repeatability

±0.1nm

±0.1nm

±0.5nm

±0.5nm

Wavelength Accuracy

±0.3 nm

±0.2 nm

±0.15 nm

±0.15 nm

Lamp

Automated 4-lamp turret

Automated 4-lamp turret

Reading Mode

T, A, C

Photometric Range

0-125%, -0.1-3.00A

Static Baseline Drift (Cu)

≤0.004A/30 min

≤0.003A/30 min

≤0.002A/30 min

≤0.002A/30 min

Dynamic Basline Drift (Cu)

≤0.006A/15 min

≤0.005A/15 min

≤0.004A/15 m

≤0.004A/15 min

Background Correction

Deuterium (D2) Background Correction

Deuterium (D2) Background Correction and Self-absorption Background Correction

Flame

Characteristic Concentration

≤0.04ug/ml

≤0.035ug/ml

≤0.02ug/ml

≤0.02ug/ml

Detection Limit (Cu)

≤0.008ug/ml

≤0.006ug/ml

≤0.004ug/ml

≤0.004ug/ml

Repeatability (Cu)

RSD≤1%

RSD≤0.6%

RSD≤0.5%

RSD≤0.5%

Acetylene Flow  Control

Auto 12-Level

Air Assist Control

Auto 4-Level

Ignition Method

PC control

Detector

Wide range UV sensitive photomultiplier tub

Burner Head

Titanium 100mm burner for air/acetylene operation

Nebulizer

High efficiency glass nebulizer

Spray Chamber

Corrosion resistant material spray chamber

Safety Protection

Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched

Graphite Furnace

Chracteristic Amount

Cd≤0.9pg, Cu≤20pg

Cd≤0.6pg, Cu≤20pg

Cd≤0.5pg, Cu≤20pg

Detection Limit (Cu)

Cd≤1.5pg, Cu≤25pg

Cd≤1.0pg, Cu≤25pg

Cd≤0.8pg, Cu≤25pg

Repeatability (Cu)

RSD≤4%

RSD≤3%

RSD≤2.5%

Heating Range of Graphite Furnace

Room temperature-3000℃

High Power Heating Range

1500-3000℃

Slope and holding time

1-255s

Heating Rate

Maximum heating rate 2000℃/s

Atomization heating mode

Light-controlled heating, Time-controlled heating, General heating

Protective Gas Flow outside Pipe

1 L/min

Protective Gas Flow inside Pipe

4-speed adjustable (0, 50, 200, 250/min flow)

Safety Protection

Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm

Auto Sampler

Optional

Data Processing

Measuring Method

Flame method, Graphite furnace method, Hydride generation-Atomic absorption method, Flame emission method

Concentration Calculation Method

Standard curve method (6 linear/non-linear fitting methods), Standard addition method, Interpolation method

Repeat measurement times

1-30 times, Calculate and give the average value of absorbance/concentration, standard deviation and relative standard deviation

Report Printing

Parameter printing, Data result printing

Dimensions/Weight

850 x 650 x 550 mm/95kg

Ambient Temp.

10 ~ 35 °C

Ambient Humidity

≦85 %

Power

110/220V, 50/60Hz

Note:

Standard specification are for all models specification for flame will be added in standard specification for models with flame specification for Graphite furnace will be added in standard specification.

Examples:

SAA-782 is Standard

SAA-782F with with Flame

SAA-782G with Graphite Furnace

SAA-782FG is with both Flame and Graphite Furnace

 

Accessories

Hydride Generator

Cooling Water Circulator

Air Compressor

50mm Nitrous Oxide  Burner

Graphite Tube

Glass Nebulizer

Hollow Cathode Lamp (HCL)

Al, Ba, Bi, Ca, Cu, Co, Cr, Fe, Ga, Hg, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Sb, Sn, Ti, Zn, Ag, As, B, Cd, Ge, Se, Si, Te, V, W, P, Au, Rb, Cs

 

Literature

AAS.pdf

Features

1.Excellent total reflection optical system ensures excellent signal-to-noise ratio of the instrument.

2. Comprehensive and safe intelligent gas control module.

3. Excellent full band deuterium lamp background correction technology and high-performance self absorption double background correction.

4. Fully automatic instrument control, light source supports high-performance element lamp, and can be completed quickly with one key.

5. Original lamp position eight lamp holder 360 degree rotation design.

6. Novel atomizer and intelligent elevator.

7. Simple, professional, automatic and fully operated RG WIN AAS workstation software under MS window system.

Specifications

Models

SAA-782

SAA-784

SAA-788

SAA-790

Optical System

Single Beam

Double Beam

Monochromator

Czerny-Turner type, focal lengths at

Grating

Holographic diffraction with 1800 lines/mm

Wavelength Range

190-900 nm

Slits

Automated slit selection 0.1, 0.2, 0.4, 0.7, 1.4, 2.0 nm

Wavelength Repeatability

±0.1nm

±0.1nm

±0.5nm

±0.5nm

Wavelength Accuracy

±0.3 nm

±0.2 nm

±0.15 nm

±0.15 nm

Lamp

Automated 4-lamp turret

Automated 4-lamp turret

Reading Mode

T, A, C

Photometric Range

0-125%, -0.1-3.00A

Static Baseline Drift (Cu)

≤0.004A/30 min

≤0.003A/30 min

≤0.002A/30 min

≤0.002A/30 min

Dynamic Basline Drift (Cu)

≤0.006A/15 min

≤0.005A/15 min

≤0.004A/15 m

≤0.004A/15 min

Background Correction

Deuterium (D2) Background Correction

Deuterium (D2) Background Correction and Self-absorption Background Correction

Flame

Characteristic Concentration

≤0.04ug/ml

≤0.035ug/ml

≤0.02ug/ml

≤0.02ug/ml

Detection Limit (Cu)

≤0.008ug/ml

≤0.006ug/ml

≤0.004ug/ml

≤0.004ug/ml

Repeatability (Cu)

RSD≤1%

RSD≤0.6%

RSD≤0.5%

RSD≤0.5%

Acetylene Flow  Control

Auto 12-Level

Air Assist Control

Auto 4-Level

Ignition Method

PC control

Detector

Wide range UV sensitive photomultiplier tub

Burner Head

Titanium 100mm burner for air/acetylene operation

Nebulizer

High efficiency glass nebulizer

Spray Chamber

Corrosion resistant material spray chamber

Safety Protection

Automatically cut off gas in case of low pressure, power failure, flame out, or burner mismatched

Graphite Furnace

Chracteristic Amount

Cd≤0.9pg, Cu≤20pg

Cd≤0.6pg, Cu≤20pg

Cd≤0.5pg, Cu≤20pg

Detection Limit (Cu)

Cd≤1.5pg, Cu≤25pg

Cd≤1.0pg, Cu≤25pg

Cd≤0.8pg, Cu≤25pg

Repeatability (Cu)

RSD≤4%

RSD≤3%

RSD≤2.5%

Heating Range of Graphite Furnace

Room temperature-3000℃

High Power Heating Range

1500-3000℃

Slope and holding time

1-255s

Heating Rate

Maximum heating rate 2000℃/s

Atomization heating mode

Light-controlled heating, Time-controlled heating, General heating

Protective Gas Flow outside Pipe

1 L/min

Protective Gas Flow inside Pipe

4-speed adjustable (0, 50, 200, 250/min flow)

Safety Protection

Cooling water flow, Protective gas pressure, Furnace body temperature, Power supply temperature, Graphite furnace installation alarm

Auto Sampler

Optional

Data Processing

Measuring Method

Flame method, Graphite furnace method, Hydride generation-Atomic absorption method, Flame emission method

Concentration Calculation Method

Standard curve method (6 linear/non-linear fitting methods), Standard addition method, Interpolation method

Repeat measurement times

1-30 times, Calculate and give the average value of absorbance/concentration, standard deviation and relative standard deviation

Report Printing

Parameter printing, Data result printing

Dimensions/Weight

850 x 650 x 550 mm/95kg

Ambient Temp.

10 ~ 35 °C

Ambient Humidity

≦85 %

Power

110/220V, 50/60Hz

Note:

Standard specification are for all models specification for flame will be added in standard specification for models with flame specification for Graphite furnace will be added in standard specification.

Examples:

SAA-782 is Standard

SAA-782F with with Flame

SAA-782G with Graphite Furnace

SAA-782FG is with both Flame and Graphite Furnace

 

Accessories

Hydride Generator

Cooling Water Circulator

Air Compressor

50mm Nitrous Oxide  Burner

Graphite Tube

Glass Nebulizer

Hollow Cathode Lamp (HCL)

Al, Ba, Bi, Ca, Cu, Co, Cr, Fe, Ga, Hg, K, Li, Mg, Mn, Mo, Na, Ni, Pb, Sb, Sn, Ti, Zn, Ag, As, B, Cd, Ge, Se, Si, Te, V, W, P, Au, Rb, Cs

 

Literature

AAS.pdf

Related Products