STO-30
Freezing Point Osmometer
Quantity :
  • Features
  • Specifications
  • Literature

Features

• It has the functions of electronic signature and user classification management, to satisfy CFR
PART21 store data query according to time which can store 3 years of testing data.
• It can carry on single-point or multi-point (31-point) linear calibration, to ensure that the instrument
has the detection accuracy of each range interval in stability.
• Instrument adopts the screw linear guide motor design, so that the operation just on a touch screen
can complete the whole test process.
• Temperature probe adopts double refrigeration system, with a short precooling time, fast detection
speed,to facilitate continuous detection.
• It can simultaneously display the osmotic pressure molar concentration value, the freezing point
value and the molar concentration ratio.
• The cooling system adopts the athermal transfer fluid design, to exempt from frequent maintenance.
• Built-in "Chinese pharmacopoeia" hundreds of injectable drug name can facilitate the preset
information of test sample.

Specifications

Measurement Range

0~3000 mOsmol

Sample Amount

100μl

Testing Duration

≤3min

Pre-cooling time

≤3min

Measurement Error

≤1%

Repeatability

≤1%

Linearity

≤1%

Environment Temperature

0~30℃ Recommended for 15~25℃

Environment Temperature

≤60%

Power supply

220V~ 50Hz 150VA

Dimensions

340mm*300mm*400mm

Weight

17kg

 

Literature

STO-30.pdf

Features

• It has the functions of electronic signature and user classification management, to satisfy CFR
PART21 store data query according to time which can store 3 years of testing data.
• It can carry on single-point or multi-point (31-point) linear calibration, to ensure that the instrument
has the detection accuracy of each range interval in stability.
• Instrument adopts the screw linear guide motor design, so that the operation just on a touch screen
can complete the whole test process.
• Temperature probe adopts double refrigeration system, with a short precooling time, fast detection
speed,to facilitate continuous detection.
• It can simultaneously display the osmotic pressure molar concentration value, the freezing point
value and the molar concentration ratio.
• The cooling system adopts the athermal transfer fluid design, to exempt from frequent maintenance.
• Built-in "Chinese pharmacopoeia" hundreds of injectable drug name can facilitate the preset
information of test sample.

Specifications

Measurement Range

0~3000 mOsmol

Sample Amount

100μl

Testing Duration

≤3min

Pre-cooling time

≤3min

Measurement Error

≤1%

Repeatability

≤1%

Linearity

≤1%

Environment Temperature

0~30℃ Recommended for 15~25℃

Environment Temperature

≤60%

Power supply

220V~ 50Hz 150VA

Dimensions

340mm*300mm*400mm

Weight

17kg

 

Literature

STO-30.pdf