SMD-60
Microwave Digestion System
SMD-60 is a new developed microwave digestion system with all vessels temperature and pressure control. With IR temperature measurement method, our digestion system can realize real-me temperature monitoring of each individual sample. With special mechanic design, the consumable free microwave digestion system is of safety and friendly operation and durability.
Quantity :
  • Features
  • Specifications
  • Literature

Features

  • Create curve according to pressure and me and display on the touch-screen
  • Set corresponding protection pressure in accordance with different conditions of experiment.
  • Users can set parameters in various functions according to their own requirements
  • Suitable for high pressure digestion, mul-vessel closed digestion and closed organic synthesis
  • Can edit, and store 255 digestion programs; each program can set up 10 digestion steps; Can set relaveparameters (pressure, me and microwave power) according to user’s requirements.
  • 360°rotation mode of digestion platform to solve heat uniformity problem.
  • High frequency resonant regulation mode, Users can set microwave power between 0-1000W according to their requirements.
  • Automatic calibration for different parameters and basic troubleshoong function

       High quality large touch-screen

  • 7 inch large touch screen for easy operation.
  • High Resolution, clear display, easy readout.
  • Mul parameters display: curves, pressure, ming, power, digestion procedure and operation procedure.
  • Menu Operation design ensures clear operation and humanity.
  • Stable and good quality display.

       High quality digestion vessel

  • Inner and outer digestion vessel design ensures safety for easy pressure testing
  • Imported TFM material for inner digestion vessel
  • Imported PEEK and glass fiber for outer digestion vessel
  • Special processing technique ensures no using of sealing bowl or explosion-proof membrane which reduces large consumable cost.
  • Special vessel structure design makes continuous working and automatic return to closed condition in case of digestion vessel over-pressure which ensures no sample and reagent waste
  • Special molding for vessel ensures uniformity Mul safety protection measures
  • High precise pressure testing system to test inner vessel pressure and display it
  • High precise controlling system makes instruments stop heating if inner vessel pressure is higher than limit to avoid any injury, or hurt.
  • Sound monitoring sensor ensures the alarm and pausing the instrument when there is abnormal sound.
  • Special protection for over-pressure or instant pressure raise.

       Door can be opened if there is any abnormal circumstances, and at the same me the instrument will stop the running microwave.

  • Self – checking and prompting function, ensure the instrument will pause and prompt relevant fault during the digestion process.
  • Reaction data of the closed digestion vessel will be transferred to CPU for analysis and do real-me monitoring the change during digestion procedure.

Specifications

Model SMD-60
Pressure Control 10 vessels
Temperature Control 10 vessels
Vessel Volume 60ml
Pressure Measutement Contactless
Temperature Measutement Contactless
Sample Quantity 6
Vessel Material

Inner vessel : imported TFM

Outer vessel: imported PEEK+glass fiber

Display External 7”inches touch screen
Pressure control range 0-10MPA
Maximum working pressure 6MPA
Pressure control accuracy ±0.01MPA
Outer vessel pressure limit 15MPA
Temperature control Range 50~300°C
Maximum working pressure 250°C
Temperature control accuracy ±0.5°C
Inner vessel temperature limit 300°C
Microwave power 0-1500w
Microwave Frequency 2450MHz
Rotation Mode 360 connuous rotaon
Microwave Leakage <5mw/cm²
Power AC 220V, 10A,50/60HZ
Dimension 520mm*560mm*460mm
Weight 43kg

 

Literature

SMD-60 Brochure

Features

  • Create curve according to pressure and me and display on the touch-screen
  • Set corresponding protection pressure in accordance with different conditions of experiment.
  • Users can set parameters in various functions according to their own requirements
  • Suitable for high pressure digestion, mul-vessel closed digestion and closed organic synthesis
  • Can edit, and store 255 digestion programs; each program can set up 10 digestion steps; Can set relaveparameters (pressure, me and microwave power) according to user’s requirements.
  • 360°rotation mode of digestion platform to solve heat uniformity problem.
  • High frequency resonant regulation mode, Users can set microwave power between 0-1000W according to their requirements.
  • Automatic calibration for different parameters and basic troubleshoong function

       High quality large touch-screen

  • 7 inch large touch screen for easy operation.
  • High Resolution, clear display, easy readout.
  • Mul parameters display: curves, pressure, ming, power, digestion procedure and operation procedure.
  • Menu Operation design ensures clear operation and humanity.
  • Stable and good quality display.

       High quality digestion vessel

  • Inner and outer digestion vessel design ensures safety for easy pressure testing
  • Imported TFM material for inner digestion vessel
  • Imported PEEK and glass fiber for outer digestion vessel
  • Special processing technique ensures no using of sealing bowl or explosion-proof membrane which reduces large consumable cost.
  • Special vessel structure design makes continuous working and automatic return to closed condition in case of digestion vessel over-pressure which ensures no sample and reagent waste
  • Special molding for vessel ensures uniformity Mul safety protection measures
  • High precise pressure testing system to test inner vessel pressure and display it
  • High precise controlling system makes instruments stop heating if inner vessel pressure is higher than limit to avoid any injury, or hurt.
  • Sound monitoring sensor ensures the alarm and pausing the instrument when there is abnormal sound.
  • Special protection for over-pressure or instant pressure raise.

       Door can be opened if there is any abnormal circumstances, and at the same me the instrument will stop the running microwave.

  • Self – checking and prompting function, ensure the instrument will pause and prompt relevant fault during the digestion process.
  • Reaction data of the closed digestion vessel will be transferred to CPU for analysis and do real-me monitoring the change during digestion procedure.

Specifications

Model SMD-60
Pressure Control 10 vessels
Temperature Control 10 vessels
Vessel Volume 60ml
Pressure Measutement Contactless
Temperature Measutement Contactless
Sample Quantity 6
Vessel Material

Inner vessel : imported TFM

Outer vessel: imported PEEK+glass fiber

Display External 7”inches touch screen
Pressure control range 0-10MPA
Maximum working pressure 6MPA
Pressure control accuracy ±0.01MPA
Outer vessel pressure limit 15MPA
Temperature control Range 50~300°C
Maximum working pressure 250°C
Temperature control accuracy ±0.5°C
Inner vessel temperature limit 300°C
Microwave power 0-1500w
Microwave Frequency 2450MHz
Rotation Mode 360 connuous rotaon
Microwave Leakage <5mw/cm²
Power AC 220V, 10A,50/60HZ
Dimension 520mm*560mm*460mm
Weight 43kg

 

Literature

SMD-60 Brochure

Related Products