High quality large touch-screen
High quality digestion vessel
Door can be opened if there is any abnormal circumstances, and at the same me the instrument will stop the running microwave.
Model |
SMD-50 |
SMD-52 |
Pressure Control |
Full Scanning |
Full Scanning |
Temperature Control |
No |
Full Scanning |
Vessel Volume |
60ml |
60ml |
Pressure Testing |
Non-contact |
Non-contact |
Temperature Testing |
No |
Non-contact |
Sample Quantity |
6 |
6 |
Vessel Material |
Inner Vessel:Imported TFM; Outer Vessel:Imported PEEK+ glass fibre |
Inner Vessel:Imported TFM; Outer Vessel:Imported PEEK+ glass fibre |
Maximum Working Pressure |
5 Mpa |
5 Mpa |
Pressure Limit |
6 Mpa |
6 Mpa |
Maximum Working Temperature |
250℃ |
250℃ |
Temperature Limit |
300℃ |
300℃ |
Outer Vessel Pressure Limit |
10 Mpa |
10 Mpa |
Screen |
7 Inch Touch Screen |
7 Inch Touch Screen |
Pressure Control Range |
0-5 MPa (0-50kg/cm2) |
0-5 MPa (0-50kg/cm2) |
Pressure Control Accuracy |
0.1MPa(1kg/cm2) |
0.1MPa(1kg/cm2) |
Microwave Power |
1000W, set from 0 to 1000W according to requirements |
1000W, set from 0 to 1000W according to requirements |
Microwave Frequency |
2450MHz |
2450MHz |
Exhaust System |
High-power Blower,exhaust speed>5cbm/min |
High-power Blower exhaust speed>5cbm/min |
Rotation Mode |
360° continuous rotaon |
360° continuous rotation |
Microwave Leakage |
<5mW/ cm2 |
<5mW/ cm2 |
Power |
AC 220V,10A,50/60Hz |
AC 220V,10A,50/60Hz |
Size |
520mm×400mm×460mm |
520mm×400mm×460mm |
Weight |
30kg |
30kg |
High quality large touch-screen
High quality digestion vessel
Door can be opened if there is any abnormal circumstances, and at the same me the instrument will stop the running microwave.
Model |
SMD-50 |
SMD-52 |
Pressure Control |
Full Scanning |
Full Scanning |
Temperature Control |
No |
Full Scanning |
Vessel Volume |
60ml |
60ml |
Pressure Testing |
Non-contact |
Non-contact |
Temperature Testing |
No |
Non-contact |
Sample Quantity |
6 |
6 |
Vessel Material |
Inner Vessel:Imported TFM; Outer Vessel:Imported PEEK+ glass fibre |
Inner Vessel:Imported TFM; Outer Vessel:Imported PEEK+ glass fibre |
Maximum Working Pressure |
5 Mpa |
5 Mpa |
Pressure Limit |
6 Mpa |
6 Mpa |
Maximum Working Temperature |
250℃ |
250℃ |
Temperature Limit |
300℃ |
300℃ |
Outer Vessel Pressure Limit |
10 Mpa |
10 Mpa |
Screen |
7 Inch Touch Screen |
7 Inch Touch Screen |
Pressure Control Range |
0-5 MPa (0-50kg/cm2) |
0-5 MPa (0-50kg/cm2) |
Pressure Control Accuracy |
0.1MPa(1kg/cm2) |
0.1MPa(1kg/cm2) |
Microwave Power |
1000W, set from 0 to 1000W according to requirements |
1000W, set from 0 to 1000W according to requirements |
Microwave Frequency |
2450MHz |
2450MHz |
Exhaust System |
High-power Blower,exhaust speed>5cbm/min |
High-power Blower exhaust speed>5cbm/min |
Rotation Mode |
360° continuous rotaon |
360° continuous rotation |
Microwave Leakage |
<5mW/ cm2 |
<5mW/ cm2 |
Power |
AC 220V,10A,50/60Hz |
AC 220V,10A,50/60Hz |
Size |
520mm×400mm×460mm |
520mm×400mm×460mm |
Weight |
30kg |
30kg |