SA-30D
Dual Cannel Flame Photometer
SA-30D comes with Dual Channel with precise and economical measurement of concentration of alkaline elements in aqueous solution and for analytical applications in process and laboratory. It is specially developed for industrial & clinical applications. SA-30D requires Propane, Butane, Natural Gas or L.P.G. as a fuel which allows flame photometric measurement up to five elements. In addition purified and dried air is required. The Model SA-30D has been developed with the objective to improve productivity and analytical performance of laboratory when measuring Sodium, Potassium, Calcium, Barium and Lithium. Set up and calibration me of instrument is much reduced, which is achieved by the ignition and optimization of flame conditions. Readings are linear over the working range of the Model SA-30D the Model SA-30D can operate in continuous or peak mode. In peak mode the Model SA-30D automatically detects a stable reading.
Quantity :
  • Features
  • Specifications
  • Literature

Features

  • Designed for industrial analysis
  • Supplied with Na, K, Li, Ba and Ca filters
  • Low temperature, single channel
  • Flame failure safety system
  • Fine 7 Course Sensivity Controls
  • Operates on Propane, Butane, Natural
  • Gas or L.P.G Supplies
  • Switchable Decimal Point

 

Specifications

Model SA-30D
Range 0 to199.9ppm
Limit of Reaction  
Na 0.2ppm
K 0.2ppm
Li 0.25ppm
Ca 15ppm
Ba 30ppm
Reproducibility <1% coefficient of variation for 20 consecutive samples using 10ppm Na set to read 50
Linearity < 2% error when 3ppm Na/K and 5ppm Li are set to read 100
Stability < 2% dris over 5min when continuously aspirating 10ppm Sample set to 50.0
Specificity Interference from Na/K and Li Equal in concentration to test element will be <0.5%
Display Digital LED
Aspiration Rate 2 to 6 ml/min

 

Literature

SA-30D Brochure

Features

  • Designed for industrial analysis
  • Supplied with Na, K, Li, Ba and Ca filters
  • Low temperature, single channel
  • Flame failure safety system
  • Fine 7 Course Sensivity Controls
  • Operates on Propane, Butane, Natural
  • Gas or L.P.G Supplies
  • Switchable Decimal Point

 

Specifications

Model SA-30D
Range 0 to199.9ppm
Limit of Reaction  
Na 0.2ppm
K 0.2ppm
Li 0.25ppm
Ca 15ppm
Ba 30ppm
Reproducibility <1% coefficient of variation for 20 consecutive samples using 10ppm Na set to read 50
Linearity < 2% error when 3ppm Na/K and 5ppm Li are set to read 100
Stability < 2% dris over 5min when continuously aspirating 10ppm Sample set to 50.0
Specificity Interference from Na/K and Li Equal in concentration to test element will be <0.5%
Display Digital LED
Aspiration Rate 2 to 6 ml/min

 

Literature

SA-30D Brochure

Related Products