Model | SHI-3010 | SHI-3010W | SHI-3010L | SHI-3010L4 |
Spectral Range |
370-1010nm |
370-1010nm |
900-1700nm |
400-1700nm |
Spectral Resolution |
>1.5nm |
>1.5nm |
>3.5nm |
>1.5nm@650nm |
Sampling Interval |
0.31nm |
0.31nm |
1.56 nm |
1.56 nm |
F-number |
F/2.6 |
F/2.6 |
F/2.6 |
F/2.6 |
Detector |
CMOS/CCD |
CMOS/CCD |
InGaAs CCD |
CMOS / InGaAs CCD |
Detector Interface |
USB3.0 |
USB3.0 |
USB3.0 |
USB3.0 |
Supply Power |
USB,3.4W |
USB,3.8W |
12V,15W |
12V,30W |
Detector Target Size |
11.26 x 5.98mm |
11.26 x 11.26mm |
9.6mmX7.68mm |
11.26 x 11.26mm |
Detector Original Resolution |
2048 × 1088 |
2048 × 2048 |
640X512 |
2048 × 2048 640X512 |
Detector Original pixel size |
5.5 µm x 5.5 µm |
5.5 µm x 5.5 µm |
15X15 µm |
5.5 µm x 5.5 µm 15X15 µm |
Bit Depth |
12 bits |
12 bits |
14 bits |
12 bits 14 bits |
Slit Width |
25 µm or customization |
25 µm or customization |
30µm or customization |
25 µm or customization |
Recommended Way To Merge Cells |
4x4 or 2x4 |
4x4 or 2x4 |
No merge or 1×2 |
According to the front row |
Number Of Spatial Channels |
480 or 960 |
2048 or 1024 |
640 |
2048 or 640 |
Number Of Spectral Bands |
300 or 600 |
512, 1024 or 2048 |
512 |
512, 1024 or 2048, 512 |
Focal Length |
16-140mm |
|||
FOV |
15.2°@f=35mm |
15.2°@f=35mm |
15.2°@f=35mm |
15.2°@f=35mm |
IFOV |
0.7mrad@f=35mm |
0.7mrad@f=35mm |
0.7mrad@f=35mm |
0.7mrad@f=35mm |
Max Frame Rate |
340 fps |
140 fps |
70Hz |
70Hz |
Size |
340mm x 340mm x 180mm |
340mm x 340mm x 180mm |
340mm x 340mm x 180mm |
440mm x 340mm x 280mm |
Weight |
<2850g |
<2850g |
<3800g |
<7500g |
Operating Temp |
-20 - 50°C |
-20 - 50°C |
-20 - 50°C |
-20 - 50°C |
Storage Temp |
-30-70°C |
-30-70°C |
-30-70°C |
-30-70°C |
Scanning |
External push-broom measurement |
|||
Data Interface |
GBE |
|||
Control Interface |
RS485 |
|||
Communication Protocol |
Pelco-D or Pelco-P |
|||
Preset Pan Speed |
100°/S |
|||
Pitch Angle Of Gimbal |
+35°~ -75° |
|||
Preset Tilt Speed |
80°/S |
|||
Manual pan speed |
0°~40°/S |
|||
Manual Tile Speed |
0°~20°/S |
|||
Level Angle |
360°infinite rotation |
|||
Vertical Angle |
+35° ~ -75° |
|||
Preset bits with automatic scanning |
Supports preset scan start bit and scan speed |
|||
Relative Humidity |
90% |
|||
Protection Grade |
IP66 |
|||
Operating Temperature |
-40° ~ +55° |
|||
Gimbal Drive Mode |
worm gear |
|||
PTZ Power Supply |
AC24V±20%,40W |
|||
PTZ Weight |
<15Kg |
|||
PTZ Size |
265mm×180mm×315mm(L×W×H) |
|||
Data Acquisition Software |
Flexible setting of exposure time, dynamic display of real-time hyperspectral images and spectral curves |
|||
Data Analysis Software |
One-click acquisition of cluster analysis, single-band, true and false color, more than 20 kinds of vegetation indices (customizable), 3D cropping of images, target spectrum recognition and other images with one click without third-party software. All the above functions can realize unattended batch processing . |
|||
With powerful hyperspectral vegetation analysis software, it can quantitatively monitor vegetation greenness and health, including red-edge normalized difference vegetation index (RENDVI), normalized difference vegetation index (NDVI), Modified red-edge normalized difference vegetation Index (MRENDVI), Modified Triangular Vegetation Index (MTVI), Modified Chlorophyll Absorption Ratio Index (MCARI), Modified Chlorophyll Absorption Index (MCARI2) and other indicators. |
||||
Software Display |
Dynamic real-time display of hyperspectral images, scientific light-dark focusing, avoiding manual visualization focusing errors |
SHI-3010-Series Brochure
Model | SHI-3010 | SHI-3010W | SHI-3010L | SHI-3010L4 |
Spectral Range |
370-1010nm |
370-1010nm |
900-1700nm |
400-1700nm |
Spectral Resolution |
>1.5nm |
>1.5nm |
>3.5nm |
>1.5nm@650nm |
Sampling Interval |
0.31nm |
0.31nm |
1.56 nm |
1.56 nm |
F-number |
F/2.6 |
F/2.6 |
F/2.6 |
F/2.6 |
Detector |
CMOS/CCD |
CMOS/CCD |
InGaAs CCD |
CMOS / InGaAs CCD |
Detector Interface |
USB3.0 |
USB3.0 |
USB3.0 |
USB3.0 |
Supply Power |
USB,3.4W |
USB,3.8W |
12V,15W |
12V,30W |
Detector Target Size |
11.26 x 5.98mm |
11.26 x 11.26mm |
9.6mmX7.68mm |
11.26 x 11.26mm |
Detector Original Resolution |
2048 × 1088 |
2048 × 2048 |
640X512 |
2048 × 2048 640X512 |
Detector Original pixel size |
5.5 µm x 5.5 µm |
5.5 µm x 5.5 µm |
15X15 µm |
5.5 µm x 5.5 µm 15X15 µm |
Bit Depth |
12 bits |
12 bits |
14 bits |
12 bits 14 bits |
Slit Width |
25 µm or customization |
25 µm or customization |
30µm or customization |
25 µm or customization |
Recommended Way To Merge Cells |
4x4 or 2x4 |
4x4 or 2x4 |
No merge or 1×2 |
According to the front row |
Number Of Spatial Channels |
480 or 960 |
2048 or 1024 |
640 |
2048 or 640 |
Number Of Spectral Bands |
300 or 600 |
512, 1024 or 2048 |
512 |
512, 1024 or 2048, 512 |
Focal Length |
16-140mm |
|||
FOV |
15.2°@f=35mm |
15.2°@f=35mm |
15.2°@f=35mm |
15.2°@f=35mm |
IFOV |
0.7mrad@f=35mm |
0.7mrad@f=35mm |
0.7mrad@f=35mm |
0.7mrad@f=35mm |
Max Frame Rate |
340 fps |
140 fps |
70Hz |
70Hz |
Size |
340mm x 340mm x 180mm |
340mm x 340mm x 180mm |
340mm x 340mm x 180mm |
440mm x 340mm x 280mm |
Weight |
<2850g |
<2850g |
<3800g |
<7500g |
Operating Temp |
-20 - 50°C |
-20 - 50°C |
-20 - 50°C |
-20 - 50°C |
Storage Temp |
-30-70°C |
-30-70°C |
-30-70°C |
-30-70°C |
Scanning |
External push-broom measurement |
|||
Data Interface |
GBE |
|||
Control Interface |
RS485 |
|||
Communication Protocol |
Pelco-D or Pelco-P |
|||
Preset Pan Speed |
100°/S |
|||
Pitch Angle Of Gimbal |
+35°~ -75° |
|||
Preset Tilt Speed |
80°/S |
|||
Manual pan speed |
0°~40°/S |
|||
Manual Tile Speed |
0°~20°/S |
|||
Level Angle |
360°infinite rotation |
|||
Vertical Angle |
+35° ~ -75° |
|||
Preset bits with automatic scanning |
Supports preset scan start bit and scan speed |
|||
Relative Humidity |
90% |
|||
Protection Grade |
IP66 |
|||
Operating Temperature |
-40° ~ +55° |
|||
Gimbal Drive Mode |
worm gear |
|||
PTZ Power Supply |
AC24V±20%,40W |
|||
PTZ Weight |
<15Kg |
|||
PTZ Size |
265mm×180mm×315mm(L×W×H) |
|||
Data Acquisition Software |
Flexible setting of exposure time, dynamic display of real-time hyperspectral images and spectral curves |
|||
Data Analysis Software |
One-click acquisition of cluster analysis, single-band, true and false color, more than 20 kinds of vegetation indices (customizable), 3D cropping of images, target spectrum recognition and other images with one click without third-party software. All the above functions can realize unattended batch processing . |
|||
With powerful hyperspectral vegetation analysis software, it can quantitatively monitor vegetation greenness and health, including red-edge normalized difference vegetation index (RENDVI), normalized difference vegetation index (NDVI), Modified red-edge normalized difference vegetation Index (MRENDVI), Modified Triangular Vegetation Index (MTVI), Modified Chlorophyll Absorption Ratio Index (MCARI), Modified Chlorophyll Absorption Index (MCARI2) and other indicators. |
||||
Software Display |
Dynamic real-time display of hyperspectral images, scientific light-dark focusing, avoiding manual visualization focusing errors |
SHI-3010-Series Brochure